Medtronic MiniMed Paradigm Veo Guía de usuario Pagina 1

Busca en linea o descarga Guía de usuario para No Medtronic MiniMed Paradigm Veo. Medtronic MiniMed Paradigm Veo User guide Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir

Indice de contenidos

Pagina 1 - A step-by-step guide

www.medtronic-diabetes.com.auThe MiniMed Paradigm™ Veo™ SystemA step-by-step guide

Pagina 2 - Your HCPs Contact Details

GETTING STARTED10Operational ModesNormal ModeThe pump operates normally.Special ModeIndicates special circumstances: low battery, low reservoir, tem

Pagina 3 - Contents

Getting Started11Refer to Chapters 10 & 13 in the MiniMed Paradigm™ Veo™ User GuideKey AlarmsEmpty ReservoirCHANGE THE RESERVOIR immediately.Weak

Pagina 4

12Use it right and use it in good health.Change your infusion set every 2 to 3 days.Refer to Chapter 5 in the MiniMed Paradigm™ Veo™ User GuideInfusio

Pagina 5 - Getting Started

13Infusion Set & Reservoirwww.medtronic-diabetes.co.uk/infusionThe Paradigm™ Veo™ insulin pump shown in pink.Understanding Infusion Set and Reserv

Pagina 6 - The Paradigm Veo Insulin Pump

14TRANSFER GUARD SNAPS ONTO INSULIN VIAL OR PEN CARTRIDGE for secure and stable reservoir llingNEEDLE INCORPORATED INTO TRANSFER GUARD to help preven

Pagina 7 - Breakdown of the Buttons

15Infusion Set & ReservoirIs the Quick-set right for you?Due to its versatile design and straight 90 degree insertion angle, you may like the Quic

Pagina 8 - Menus and Menu Options

16Refer to Chapter 5 in the MiniMed Paradigm™ Veo™ User Guide12534GETTING CONNECTEDInserting the Infusion SetInsert the Infusion SetWash hands thoroug

Pagina 9 - Status Screens

17Infusion Set & ReservoirRefer to Chapter 5 in the MiniMed Paradigm™ Veo™ User GuideFilling the Reservoir11.8mlStep 2INSERT the needle of the blu

Pagina 10 - Operational Modes

18GETTING CONNECTEDFill the Infusion Set TubingStep 1A C TStep 2A C TStep 3A C TStep 4A C TStep 5Insert the reservoir (with set connected)into the pum

Pagina 11 - Key Alarms

19Infusion Set & ReservoirInsertion of the Medtronic Quick-Set Infusion SetStep 4REMOVE the needle protector (blue cone) by unscrewing it.Step 1IN

Pagina 12 - Infusion Set and Reservoir

3www.medtronic-diabetes.co.ukYour HCPs Contact DetailsYour Endocrinologist:Phone number:Email:Your Diabetes Educator:Your Diabetes Centre:Address:Phon

Pagina 13 - Getting Connected

20Step 7PRESS the plunger with your index nger to release the introducer needle.Step 9Carefully WITHDRAW the introducer needle.Step 6SQUEEZE the 2 wh

Pagina 14 - Medtronic Paradigm Reservoirs

21Infusion Set & ReservoirInsertion of the Medtronic Silhouette Infusion SetStep 1OPEN the mouth of the Sil-Serter inserter.Step 4LOAD the Sil-Se

Pagina 15 - Choice and Flexibility

2230° Step 5PLACE the feet of the Sil-Serter on the insertion site and position at an approximately 30 degree angle.Step 7OPEN the Sil-Serter mouth a

Pagina 16 - Inserting the Infusion Set

23Infusion Set & ReservoirBasal & Bolus23Refer to Chapters 4, 6, & 7 in the MiniMed Paradigm™ Veo™ User GuideBasal and BolusGETTING FREEDO

Pagina 17 - Filling the Reservoir

24Understanding Basal and Bolus For this section, you will need:Starting hourly Basal rate •Sensitivity factor •Insulin to carb ratio (or exchange)•

Pagina 18 - Fill the Infusion Set Tubing

25 Basal & BolusRefer to Chapters 4, 6, & 7 in the MiniMed Paradigm™ Veo™ User Guidegetting freedomSetting the Basal RateStep 1Select Basal SE

Pagina 19 - Infusion Set

26Basal ReviewTo check your Basal rates and times:getting freedomStep 1To check your BASAL RATES & TIMES choose “Basal REVIEW” from the Basal men

Pagina 20

Basal & Bolus27Medtronic Bolus Wizard CalculatorThe Medtronic Bolus Wizard calculator performs the calculations needed to manage your insulin dos

Pagina 21

28Programming the Bolus Wizard CalculatorStep 1From the MAIN menu choose “Bolus” and press A C T .Step 2From the Bolus menu choose “Bolus SETUP” and p

Pagina 22

Basal & Bolus29Using the Bolus Wizard CalculatorStep 1Press A C T 3 times to access the Bolus Wizard™.Step 2Use to enter BLOOD GLUCOSE mmol/L an

Pagina 23 - Basal and Bolus

INTRODUCING THE PARADIGM™ VEO™ SYSTEMContentsIntroducing the Paradigm™ Veo™ System 4• Paradigm Veo System Overview 6• Menu & Menu Options 8•

Pagina 24 - Getting F reedom

30Setting the Missed Bolus Remindergetting freedomStep 1Select Add Reminder on the MISSED Bolus REMINDER screen, then press A C T .Step 2The Start Tim

Pagina 25 - Setting the Basal Rate

Basal & Bolus31getting freedomStep 1Select Review Reminders on the MISSED Bolus REMINDER screen and press A C T .Step 1Select Delete Reminder on

Pagina 26 - Basal Review

32Select CANCEL TEMP BASAL from the Basal Menu and press A C T .Temporary Basal RateStep 1Select Basal SETUP from the Basal menu and press A C T .Step

Pagina 27

Basal & Bolus33Express BolusCancelling a Bolus (Temporary stop)Setting the Express BolusStep 1Click on Bolus and press A C T three times.Step

Pagina 28 - Reviewing settings

34Note: If you have any questions or concerns, please consult your healthcare professional before making any therapy changes.Continuous Glucose Monito

Pagina 29

CGM35CGMGetting Controlwww.medtronic-diabetes.co.uk/cgmUnderstanding the benefits of Continuous Glucose Monitoring For this section, you will need:Medt

Pagina 30 - Add a Reminder

36Refer to Chapters 8 & 9 in the MiniMed Paradigm™ Veo™ User GuideInsertion of SensorWash your hands thoroughly before starting.You will need the

Pagina 31 - Delete a Reminder

CGM37Refer to Chapters 8 & 9 in the MiniMed Paradigm™ Veo™ User GuideStep 1PLACE the sensor in the Sen-serter (the black rings should no longer be

Pagina 32 - Temporary Basal Rate

38Starting a Sensor1. Sensor StartOnce the sensor is inserted under the skin:WAIT• 5-15 minutes; this is the time required for the sensor to be wette

Pagina 33 - Express Bolus

CGM39GETTING CONTROLKey CGM AlarmsEnter blood glucose for sensor calibration> Main Menu > Sensor > Enter BG > Enter BG > Use to enter

Pagina 34 - GETTING CONTROL

A step-by-step guide to using the Paradigm® Veo™44EXPRESS BOLUS ESCAPEto prior screenACT conrm information or menu selectionPARADIGM CONNECTOR INFUSI

Pagina 35 - Getting Control

40Trend Graphs3 - hour graphFrom the home screen, press once to access the 3 hour graph. To see variations in your glucose levels over 5 minutes pr

Pagina 36 - Insertion of Sensor

CGM41Understand the Trend GraphsAll graphs show High and Low Glucose Limits lines, a continuous Sensor Glucose (SG) measurement line, a data section,

Pagina 37 - Inserting the Sensor

42GETTING CONTROLRefer to Chapters 8 & 9 in the MiniMed Paradigm™ Veo™ User GuideTurning glucose alerts on:AlertsStep 1From the MAIN menu choose

Pagina 38 - Starting a Sensor

CGM43Refer to Chapters 8 & 9 in the MiniMed Paradigm™ Veo™ User GuideGETTING CONTROLGlucose Limits Step 1From the SENSOR menu choose “EDIT SETTI

Pagina 39 - Key CGM Alarms

44Refer to Chapters 8 & 9 in the MiniMed Paradigm™ Veo™ User GuideGETTING CONTROLPredictive AlertsTo set up the Predictive alerts:To set up the ti

Pagina 40 - Trend Graphs

CGM45GETTING CONTROLRefer to Chapters 8 & 9 in the MiniMed Paradigm™ Veo™ User GuideRate of Change AlertsTo set up the Rate of Change alerts:Step

Pagina 41 - Understand the Trend Graphs

46Low Glucose SuspendPurposeThe •Low Glucose Suspend (LGS) is a feature designed to help reduce the risk of severe hypoglycaemia. If the feature is t

Pagina 42

CGM47Note: Patient can override Low Glucose Suspend at any time.GETTING CONTROLThe Paradigm Veo insulin pump and CGM functionalities aim at helping p

Pagina 43 - Glucose Limits

48OPTIONAL EXTRASMedtronic CareLink® Therapy Management Software: for you and your Healthcare ProfessionalFor you - Medtronic CareLink® PersonalAllows

Pagina 44 - Predictive Alerts

49Optional ExtrasParadigm Veo SKINSBlue GooParadigm Veo SKINSLightning BoltParadigm Veo SKINSGreen AuraParadigm Veo SKINSJelly BeansParadigm Veo SKINS

Pagina 45 - Rate of Change Alerts

Getting Started5www.medtronic-diabetes.co.uk/gettingstartedINFUSION SETThe Paradigm™ Veo™ insulin pump shown in purple.Getting StartedUnderstanding th

Pagina 46 - Low Glucose Suspend

50NotesMINIMED PARADIGM™ VEO™ SYSTEM

Pagina 48 - Bringing it all together

Safety InformationInsulin Pump Therapy and MiniMed Insulin Infusion PumpsPatients should always discuss the benets and potential risks with a clinici

Pagina 49 - Personalise Your Pump

6Refer to Chapter 3 in the MiniMed Paradigm™ Veo™ User GuideGETTING STARTEDA patient-friendly insulin pumpWith the Paradigm Veo pump:You only need to

Pagina 50 - MINIMED PARADIGM™ VEO™ SYSTEM

Getting Started7A C TBreakdown of the ButtonsEXPRESS BOLUS to set a BolusGETTING STARTEDSimple buttons for simple useThe buttons on the Paradigm Veo i

Pagina 51

GETTING STARTEDMenus and Menu OptionsNavigationPress the A C T button from the MAIN MENU to get to the sub-menus.Press the button from a submenu scre

Pagina 52 - Australia

Getting StartedGetting StartedPUMP STATUS SCREENStatus ScreensSENSOR STATUS SCREENPress the button to go to the PUMP AND SENSOR STATUS screens.STATUS

Comentarios a estos manuales